Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Arq. bras. oftalmol ; 83(2): 141-145, Mar.-Apr. 2020. tab, graf
Article in English | LILACS | ID: biblio-1088976

ABSTRACT

ABSTRACT Purpose: To compare the postoperative refractive predictability of IOLMaster 500 and Pentacam HR on the basis of keratometry and anterior chamber depth values in eyes with an indication for multifocal intraocular lens (IOL) implantation. Methods: This was a retrospective study conducted on 118 eyes treated with phacoemulsification and multifocal intraocular lens implantation. Only the eyes that achieved emmetropia in the dynamic refraction performed on postoperative day 30 were included. Haigis' formula was used in each case to calculate the intraocular lens power, and the intraocular lens with the target refraction closest to emmetropia was implanted. Four lens calculation scenarios were tested by combining keratometry and anterior chamber depth measurements obtained using the two devices. Results: IOLMaster 500 and Pentacam HR differed with regard to mean keratometry (D 0.07 ± 0.03 D; p=0.0065) and anterior chamber depth (D 0.08 ± 0.01 mm; p<0.001). In the analysis of covariance, the following differences were obtained using the Haigis' formula when confronted with the biometric values obtained by inserting keratometry and anterior chamber depth values, respectively: Penta/IOL x IOL/Penta (0.13 ± 0.03; p<0.0001); Penta/Penta × IOL/Penta (0.13 ± 0.03; p<0.0001); Penta/IOL × IOL/IOL (0.11 ± 0.03; p=0.001); Penta/Penta × IOL/IOL (0.11 ± 0.03; p=0.002); IOL/IOL × IOL/Penta (0.02 ± 0.03; p=0.865); and Penta/IOL × Penta/Penta (0.002 ± 0.03; p=0.99). The difference was smaller when measuring the anterior chamber depth using the IOLMaster 500, regardless of which device was used to measure keratometry. Conclusions: Pentacam HR significantly differed from IOLMaster 500 when calculating keratometry. As regards the anterior chamber depth, the two devices were equally accurate.


RESUMO Objetivo: Comparar a previsibilidade refrativa pós-operatória do IOLMaster 500 e Pentacam HR com base nos valores de ceratometria e profundidade de câmara anterior nos olhos com indicação de implante de lentes intraoculares multifocais. Métodos: Estudo retrospectivo realizado em 118 olhos tratados com facoemulsificação e implante de lentes intraoculares multifocal. Apenas os olhos que atingiram a emetropia na refração dinâmica no 30º dia pós-operatório foram incluídos. A fórmula de Haigis foi usada em cada caso para calcular o poder das lentes intraoculares, e a lente intraocular com a refração alvo mais próxima da emetropia foi implantada. Cenários de cálculo de quatro lentes foram testados pela combinação de medidas de ceratometria e profundidade de câmara anterior obtidas usando os dois dispositivos. Resultados: IOLMaster 500 e Pentacam HR diferiram quanto à média de ceratometria (D 0,07 ± 0,03 D; p=0,0065) e profundidade de câmara anterior (D 0,08 ± 0,01 mm; p<0,001). Na análise da covariância, as seguintes diferenças foram obtidas usando a fórmula de Haigis quando confrontadas com os valores biométricos obtidos pela inserção dos valores de ceratometria e profundidade de câmara anterior, respectivamente: Penta/IOL x IOL/Penta (0,13 ± 0,03; p<0,0001); Penta/Penta x IOL/Penta (0,13 ± 0,03; p<0,0001); Penta/IOL x IOL/IOL (0,11 ± 0,03; p=0,001); Penta/Penta x IOL/IOL (0,11 ± 0,03; p=0,002); IOL/IOL x IOL/Penta (0,02 ± 0,03; p=0,865); Penta/IOL x Penta/Penta (0,002 ± 0,03; p=0,99). A diferença foi menor ao medir a profundidade da câmara anterior usando o IOLMaster 500, independentemente de qual dispositivo foi usado para medir a ceratometria. Conclusões: O Pentacam HR diferiu significativamente do IOLMaster 500 no cálculo de ceratometria. Quanto à profundidade da câmara anterior, os dois dispositivos foram igualmente precisos.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Phacoemulsification/methods , Cornea/pathology , Corneal Topography/instrumentation , Lens Implantation, Intraocular/methods , Multifocal Intraocular Lenses , Anterior Chamber/pathology , Postoperative Period , Reference Values , Refraction, Ocular/physiology , Time Factors , Visual Acuity/physiology , Predictive Value of Tests , Retrospective Studies , Biometry , Treatment Outcome , Cornea/diagnostic imaging , Interferometry/instrumentation , Interferometry/methods , Anterior Chamber/diagnostic imaging
2.
Arq. bras. oftalmol ; 72(4): 462-466, July-Aug. 2009. graf, tab
Article in Portuguese | LILACS | ID: lil-528010

ABSTRACT

OBJETIVO: Avaliar o efeito do "cross-linking" corneano na ceratopatia bolhosa sintomática e seu impacto na acuidade visual, espessura corneana e sintomatologia dolorosa. MÉTODOS: Doze pacientes com ceratopatia bolhosa sintomática foram incluídos. Exame clínico com questionário específico para a pesquisa com escala de dor (escala visual analógica numérica), acuidade visual e mensuração da espessura corneana foi realizada pré "cross-linking" corneano, 7, 30 e 60 dias após. Em todos os pacientes o tratamento com UVA-crosslinking foi realizado após abrasão do epitélio corneano na lâmpada de fenda e instilação de solução de riboflavina 0,1 por cento a cada 5 minutos por 30 minutos. Após esse período o paciente foi submetido à exposição à luz ultravioleta A (UVA), utilizando riboflavina e anestesia tópica a cada 5 minutos por 30 minutos. O paciente utilizou colírios de ofloxacina 0,3 por cento e lágrima artificial até completa reepitelização. O teste de Friedman foi usado para comparar as médias das frequências da acuidade visual, sintomatologia dolorosa e espessura central da córnea. Os valores de "p" menor que 0,05 foram considerados como estatisticamente significantes. RESULTADOS: Doze olhos de 12 pacientes com erosões epiteliais recorrentes foram tratados. O tempo de seguimento foi de dois meses. Foi observada redução significante da dor (p<0,001). As medidas da espessura corneana e da acuidade visual não sofreram alterações estatisticamente significantes. CONCLUSÃO: Foi constatado o potencial de aplicação do "cross-linking" corneano no tratamento de pacientes com dor causada por ceratopatia bolhosa. É necessário maior seguimento para confirmar se os resultados podem ser reproduzidos em longo prazo.


PURPOSE: To evaluate the corneal cross-linking (CXL) effect on symptomatic bullous keratopathy, and its impact on the visual acuity, corneal thickness and pain symptomatology. METHODS: Twelve patients with symptomatic bullous keratophaty were included. A clinical examination with a specific questionnaire (pain scale - visual numeric analog scale), visual acuity, and corneal thickness measures was performed before corneal cross-linking and 7, 30 and 60 days after the procedure. In all patients, the treatment with the UVA-crosslinking was done after corneal abrasion on the slit-lamp and instillation of 0.1 percent riboflavin in saline for every five minutes, lasting 30 minutes. Subsequently, the patient underwent the UVA light exposure, using riboflavin and topical anesthesia, every five minutes lasting 30 minutes. The patient received 0.3 percent ofloxacine drops, and artificial tears until complete reepithelization. The Friedman test was used to compare the means of frequencies of visual acuity, pain symptoms and corneal thickness. A "p" value <0.05 was considered for rejecting the null hypothesis. RESULTS: Twelve eyes from 12 patients with recurrent epithelium erosions were treated. The mean follow-up was two months. Significant pain reduction was observed (p<0.001). Corneal thickness and visual acuity measurements presented with no significant difference. CONCLUSION: The potential use of cross-linking in the treatment of bullous keratopathy pain was proved to be likely. A longer follow-up to confirm whether these results can be reproduced in the long term is necessary.


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Corneal Diseases/therapy , Photosensitizing Agents/administration & dosage , Riboflavin/administration & dosage , Ultraviolet Rays , Corneal Topography , Cross-Linking Reagents , Follow-Up Studies , Pain Measurement , Treatment Outcome , Visual Acuity
SELECTION OF CITATIONS
SEARCH DETAIL